News Stories

Got a tip or story? Share it with MAGNIFYI®.


Reminder: New Virtual Power Plant Program Adopted

On November 12, 2026 the New Jersey BPU issued an order establishing the PowerUp NJ program that is comprised of two utility-administered, opt-in programs for residential and small commercial “host customers” who enroll devices that can respond to dispatch events, in which utilities call upon participating resources to address grid stress conditions. Each utility must develop a PowerUp NJ proposal, which must include overall peak demand reduction targets of at least 3.5%, with at least 3.0% contributed by the virtual power plant (VPP) program.

Among other things the New Jersey BPU: (1) adopted Staff recommendations for both programs; (2) directed utilities to credit exports from any “NEM-eligible solar-plus-storage system at the applicable NEM rate provided the storage component is configured to operate in a NEM integrity mode,” clarifying that “customers with existing solar-plus-storage systems that are currently net metered and lack permission to export from the storage component of their system remain eligible to receive NEM credit for their solar exports regardless of whether the storage component of their system is configured to operate in a NEM integrity mode”; (3) directed utilities “to file petitions for Block 1 program designs that are consistent with” minimum filing requirements (MFRs) modeled on those for energy efficiency (EE) and conservation programs; (4) adopted “Operating Expense treatment for program costs recovered as current expenses, without a separate equity return on those reimbursements,” and directed Staff “to evaluate a mechanism under which [utility] earnings are tied to and may scale with verified ratepayer savings or other quantitative performance benchmarks that are reasonably related to ratepayer benefits,” without recovery being “conditioned on achievement of the performance target”; and (5) included attachments providing: (i) MFRs for the VPP Interim Program and Block 1; (ii) Staff responses to comments on straw proposals for the VPP Interim Program and Block 1; (iii) example annual Block 1 Incentive Payment Calculation; (iii) benefit-cost analysis (BCA) methodologies and assumptions for the VPP Interim Program and Block 1; and (iv) Block 1 BCA.

VPP Interim Program
This is Phase 1 of BPU’s two-phase VPP implementation framework. It offers compensation, using one of two participation models, for load reduction through eligible devices, including smart thermostats, EV chargers, and electric water heaters. Under the distributed energy resource (DER) provider participation model, the utility pays the host customer for performance, either directly or through a contractor, and separately pays the DER provider for reliably providing device data and carrying out dispatch signals. Under the Site Aggregator participation model, the aggregator enrolls an entire site, the utility pays the aggregator for kW delivered, and the aggregator compensates host customers. The site aggregator bears the performance risk and will typically retain a share of the compensation for services.

Additional VPP Interim features include:

  • technology-neutral, open to all DER types capable of delivering dispatchable demand reduction (DR) on a reliable, event-driven basis, with a minimum aggregation size of 10kW per dispatch event;
  • customers may enroll separate devices at a single site through the same or separate DER providers;
  • utility measures a site’s net load reduction at the retail meter and, if a customer is enrolled through a DER provider and has Block-1 participating devices, removes any contribution from those devices;
  • open to standalone storage and solar-plus-storage systems, but not to solar-only systems on net energy metering (NEM) tariffs; and
  • the program will run 10/1/27 – 9/30/29.

Block 1 Program
This is Block 1 of the distributed storage segment (Phase 2) of the Garden State Energy Storage Program (GSESP). It pays performance incentives for energy storage devices that respond to utility dispatch events. Host customers must contract with a DER provider, who enrolls and dispatches their storage devices and interfaces with the utility. The provider receives direct monetary payment of the full incentive, then passes an agreed upon share to the customer, either as a direct monetary payment or in the form of a reduced lease or contract payment.

Additional Block 1 features include:

  • all customers, including those served by third-party suppliers (TPSs), are eligible to participate that are eligible for residential or small commercial default service (BGS-RSCP) supply and install behind-the-meter (BTM) energy storage systems (ESSs);
  • customers are ineligible if simultaneously enrolled in a DR Resource, DER aggregation (DERA), or other supply-side resource in the PJM wholesale markets that provides compensation for the same services as, or impedes the expected operation of, Block 1 resources;
  • all storage devices at a site must be enrolled as a single resource by a single DER provider;
  • maximum annual performance-based incentives, for 10 years, of: (i) new storage – $200/kW; and (ii) existing storage – $100/kW;
  • 150MW of new storage, allocated as follows: (i) PSE&G – 73MW; (ii) JCP&L – 52MW; (iii) ACE – 21MW; and (iv) RECO – 4MW;
  • 100MW of existing storage, allocated as follows: (i) PSE&G – 49MW; (ii) JCP&L – 34MW; (iii) ACE – 14MW; and (iv) RECO – 3MW; and
  • Staff is authorized to reallocate capacity during the enrollment period if necessary.

Customers may enroll in both programs and may have separate DER providers managing their VPP Interim and Block 1 devices. However, if all devices are managed by a site aggregator, any energy storage device would participate in the VPP Interim program, not Block 1. No device may be enrolled in more than one of the VPP Interim, Block 1, and Triennium 2 DR programs at a time.

See press release. 

See also the PowerUp NJ Program page, the VPP program proceeding, QO26030099, and the GSESP, Phase 2 proceeding, QO26040116,.